Product Certifications for Measuring Instruments in CIS Countries

Oct 24, 2018 · * Ukraine became an associate CIS member in 1994 but informally withdrew participation in 2014 after Russia annexed Crimea. Ukraine officially ended its CIS membership in May 2018. ** In addition to a metrology certificate, some countries require a Legal Calibration Certificate (LCC), also referred to as a First Calibration Certificate.

Get Price

Flow Meter Calibration Services | Tektronix

Flow Meter Calibration Capabilities. Tektronix provides fully-accredited flow meter calibration services. Regular calibration of your flow meter instruments ensure that the flow metermeasurements are as accurate as their specifications say they are. Our comprehensive flow meter calibration services can be custom-tailored to meet your specific requirements—either at your site or through our network of mobile and depot labs.

Get Price

Calibration | KROHNE U.S.A

For calibration we only use direct comparison of measurands (e.g. we calibrate our Coriolis mass flowmeters with a gravimetric weighing system). Our calibration rigs are the most accurate used in measuring device production worldwide: the accuracy of the reference is usually 5 to10 times better than that of the meter under test.

Get Price

Calibration Services - Intertek

Engaging reliable calibration services assists oil and gas organisations in preventing drifting and inaccuracies and ensures that equipment continues to meet its manufacturer’s specifications. In terms of safety and compliance, apparatus needs to satisfy quality assurance and quality control requirements, as well as operate in accordance with

Get Price

Instrument Calibration Services Solutions - Micro Precision

With more than 50 years of service experience, Micro Precision Calibration is a global leader offering customers around the world an easy path to instrument calibration services, standards compliance testing, equipment repair sales solutions, asset management, and more.

Get Price

ODS Metering Systems B.V. - Our product is Accurate Measurement

Crude Oil Metering Skid, 4 turbine meter runs, sphere prover, sampling system. Import / Export Gas Metering Skid, coriolis meter runs, analyser system. Allocation meter points. Process meter points. Metering Control System

Get Price

PRESS RELEASE: Fluke Ti450 sf 6 Gas Leak Detector Reduces

The infrared camera includes the award-winning LaserSharp® Auto Focus that delivers instant focus on a single target using a built-in laser distance meter to calculate and display the distance to the designated target with pinpoint accuracy.

Get Price

Calibration of Survey Meters and Measurements of Contamination

Jan 18, 2011 · Reading the Meter During Calibration To minimize exposures to the calibration personnel, the meter might be read remotely. This might be accomplished by: • Viewing the meter on a remote monitor - a video camera is aimed at the meter display Radiological Calibration – Exposure Rate 31 py • Viewing the meter reading (or its reflection in a

Get Price

Calibration - Wikipedia

As an example, a manual process may be used for calibration of a pressure gauge. The procedure requires multiple steps, [citation needed] to connect the gauge under test to a reference master gauge and an adjustable pressure source, to apply fluid pressure to both reference and test gauges at definite points over the span of the gauge, and to compare the readings of the two.

Get Price

Traceable Calibration for Vibration Meters

Ultimus Human Vibration Meter HAVs OR Whole Body: £385.00: HS-620: Hansford Sensors: Vibration Meter: £180.00: HS-630: Hansford Sensors: Vibration/ Temperature Meter: £180.00: PCE_VT 2700: PCE Instruments: Vibration Meter: £180.00: SV103: Svantek: Personal Human Vibration Exposure Meter: £385.00: SV106: Svantek: Human Vibration Meter HAVs OR Whole Body: £385.00: SV106 HWBV: Svantek

Get Price

How to Calibrate a Flow Meter | Calibration Procedures Methods

What Is Flow Meter Calibration?Flow Meter Calibration vs. RecalibrationHow to Calibrate A Flow MeterModular, Engineered-To-Order Process Flow Systems with IFSFlow meter calibration is the process of comparing the pre-set scale or metering of a flow meter to a standard scale of measurement and adjusting its metering to conform to the standard. Calibration is an essential aspect of instrumentation in a broad range of industries that require high-accuracy measurements with a negligible percentage of error e.g. in Oil & Gas, Petrochemical, and manufacturing.Flow meters are calibrated by comparing and adjusting their metering to correspond with a prede...

Get Price

SIM Guidelines on the calibration of oscillation-type density

It is the responsibility of the laboratory of calibration and the client to agree prior to calibration, about the range of density or values of density in which the measuring instrument will be calibrated in accordance to the use of the oscillation-type density meter, as well as the cost of the calibration.

Get Price

Calibration service - WIKA South Africa

Every measuring instrument wears due to mechanical, chemical, or thermal stress, and therefore, over time, provides changing readings. Although this can not be prevented, it can be detected in good time by calibration. Use our calibration service for your pressure gauges to minimize safety risks. Your advantages

Get Price

micro-gloss Glossmeter | Appearance | BYK Instruments

Accurate readings require reliable calibration. The gloss meter and calibration holder make a perfect couple - the calibration standard is always protected in the holder of the micro-gloss. The intelligent auto diagnosis of the gloss meter is a unique feature which guarantees long-term calibration stability and tells you when to calibrate.

Get Price

Mobile calibration setup for mass flow meters | Bronkhorst

Calibration is comparing the measurement value of a device under test - DUT - with a known (reference) quantity. Results of a calibration are stored in a calibration certificate. In this particular case, Bronkhorst has developed a mobile calibration setup for a customer in the chemical industry who uses a lot of mass flow meters and flow

Get Price

Flow Meter Accuracy Repeatability | Bronkhorst

How accurate your meter needs to be is important when selecting a flow meter, because usually the more accurate a meter, the higher the price. When you see an accuracy specification, it should be expressed as a percent of Full Scale (FS) or Reading (Rd or RD).

Get Price

UVC Disinfection Light Measurement, Meters Detectors

The ILT2400-UVC peaks at 265 nm, UV-C spectrum where most pathogens, including the COVID-19 virus, are deactivated. System includes the meter, detector, rugged carrying case, and an ISO17025 accredited, NIST traceable calibration certificate. Made in the USA. Click on image to view detailed specifications or purchase meter

Get Price

Calibration and Repairs » Lighthouse Worldwide Solutions

CALIBRATION AND REPAIRS. Lighthouse maintains Calibration Service Centers in eight different locations around the world. Our service management teams track the calibration schedules for customers and assure that their instruments are consistently maintained and calibrated. You may reach us via phone at (800) 945-5905 / (541) 770-5905 or email at [email protected] if you have any questions or need any help with the Calibration Repair Request Form that you can access via the following link:

Get Price

Gas Detection Infrared Camera: Fluke Ti450 sf 6 | Fluke

Infrared for every day. SF 6 gas detection when you need it. Increase efficiency and save money with a top performing infrared camera that delivers pinpoint, state-of-the-art SF 6 detection - conduct two critical functions with a single tool.

Get Price

Contact BK | Brüel Kjær Australia

Brüel Kjaer Australia HQ. Suite 2, 6-10 Talavera Road. PO Box 349, North Ryde NSW 2113. Australia. Phone: +61 02 9889 8888 Fax: +61 02 9889 8866

Get Price

Calibration Intelligent Automatic Sf6 Analyzer Gas Density

Auto finish the conversion between pressure measurement and 20℃, thereby finish the dynamic automatic compensation between pressure and temperature. And display the pressure of the measured environment, the equivalent pressure under 20℃, temperature. It solves the problem of sf 6 gas density relay field calibration difficulty thoroughly. 4.

Get Price

IAEA SAFETY RELATED PUBLICATIONS

ukraine united arab emirates united kingdom of great britain and dose equivalent rate meter — calibration with reference instrument without monitor (calibration

Get Price

ETC(Electronics Testing Center,Taiwan) - Calibration of

Illuminance (LUX) meter, UV meter, CRT color analyzer, UV intensity meter, luminance meter, chroma meter. Antenna Testing/Calibration Our antenna calibration laboratory has been accredited by Taiwan Accreditation Foundation (TAF).

Get Price

METERS | GAUGES | TESTERS SUPPLY / CALIBRATION in KUWAIT

We are Authorised ISO/IEC 17025 Accredited Calibration service provider with state-of-the art Lab facilities. We are the only SAUDI ARAMCO Approved Calibration service provider and only ISO 17025 Accredited Calibration lab for Energy meter in the UAE…

Get Price

Magnetic Flow Meters | Water Industry | Siemens Australia

Every Magflo meter produced is unique and is identified by an individual serial number, which can be used to find all build information and acquire a copy of the Calibration certificate at any time. Each meter is delivered with a printed copy of its Calibration Certificate in an envelope labelled “Important Documents”.

Get Price

Contact BK Denmark (HQ) - Brüel Kjær | BK

Hottinger Brüel Kjær A/S. Skodsborgvej 307. DK-2850 Nærum. Denmark. Phone: +45 7741 2000 Fax: +45 4580 1405

Get Price

C-700R-U | Sekonic

User-friendly design: 270 degrees swivel head, dark calibration without a cap, large 4.3” color touch panel LCD and Customize function. C-700 Series Utility Software (download from www.sekonic.com) offers easy settings in the meter and analysis of memorized data in a computer.

Get Price

YSI ProDSS Water Quality Meter Calibration Tips | The

Jun 11, 2018 · Since the 'zero' calibration environment may not be 0 FNU due to contaminated standard, dirty sensors, dirty calibration cup, and/or dirty sensor guard, a Calibration Value from 0 to 1 FNU can be entered. The following tips can help eliminate negative turbidity readings: Use a calibration cup and sensor guard that is exclusively used for

Get Price

Fluke Biomedical Calibration and Repair Services | Fluke

Accredited medical equipment calibration and repair facilities by Fluke Biomedical Please see important information about the United States service center. Highly credentialed and equipped with an NVLAP Lab Code 200566-0 accredited laboratory in Cleveland, Fluke Biomedical calibrates and repairs instruments of industry makes and models from all

Get Price